DOI 10.2459/jcm.0000000000000179

Медицинская библиотека · Journal of cardiovascular medicine (Hagerstown, Md.) · 2015

One-year follow-up of conduction disturbances following transcatheter aortic valve implantation.

Salizzoni Stefano, Anselmino Matteo, Fornengo Cristina, Giordana Francesca, La Torre Michele, Moretti Claudio, D'Amico Maurizio, Omedé Pierluigi, Marra Sebastiano, Rinaldi Mauro, Gaita Fiorenzo

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: To describe the postprocedural and 1-year follow-up incidence of heart conduction disturbances in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).

METHODS

Ninety-five patients were enrolled from 2008 to 2011 (mean age 81.8 ± 7.2 years, 63.1% women). Clinical and ECG data were recorded at admission, discharge, and 3, 6 and 12 months following TAVI.

RESULTS

Fifty-seven Edwards SAPIEN (31 transapical, 26 transfemoral) and 38 transfemoral CoreValve implants were used. Two (2.1%) patients died during the procedure and 11 (11.6%) patients received a pacemaker prior to discharge (7 CoreValve, 3 transapical, 1 transfemoral SAPIEN; P = 0.18). Among the surviving patients not receiving a pacemaker, TAVI increased the PQ interval (176 ± 29 vs. 188 ± 36 ms; P = 0.001), QRS width (90 ± 15 vs. 108 ± 26 ms; P < 0.001), and first-grade atrioventricular block (17 vs. 29%; P < 0.001). Postprocedural complete left bundle branch block was reported most in transapical (from 10 to 36%; P = 0.01) and CoreValve (from 8 to 64%; P < 0.001) recipients compared to the transfemoral SAPIEN group. At the 12-month follow-up, 24 (25.3%) patients had died [two (2.1%) sudden deaths] and four (4.2%) required pacemaker implantation. Among the survivors not receiving a pacemaker at the 1-year follow-up, the PQ interval (178 ± 27 vs. 188 ± 36 ms; P = 0.39) remained unchanged in the ECG, whereas the QRS width (100 ± 22 vs. 108 ± 26 ms; P = 0.008) decreased compared to measurements taken at discharge.

CONCLUSION

Conduction disturbances following TAVI primarily develop during hospitalization and subsequently stabilize. However, the small percentage of patients suffering sudden death or pacemaker implantation requires attention.

Для цитирования: Salizzoni Stefano, Anselmino Matteo, Fornengo Cristina, Giordana Francesca, La Torre Michele, Moretti Claudio, D'Amico Maurizio, Omedé Pierluigi, Marra Sebastiano, Rinaldi Mauro, Gaita Fiorenzo. One-year follow-up of conduction disturbances following transcatheter aortic valve implantation.. Journal of cardiovascular medicine (Hagerstown, Md.). 2015. DOI: 10.2459/jcm.0000000000000179.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.