Early Postoperative Intraocular Pressure is Associated With Better Pressure Control After XEN Implantation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cutolo Carlo A, Iester Michele, Bagnis Alessandro, Bonzano Chiara, Negri Letizia, Olivari Sara, Cappelli Francesca, Testa Valeria, Sindaco Daniele, Pizzorno Chiara, Scotto Riccardo, Saccheggiani Michela, Traverso Carlo E

Аннотация

UNLABELLED: PRéCIS:: Gel stent implantation is a bleb-forming surgery designed to achieve predictable pressure drop. An early low intraocular pressure (IOP) is associated with the long-term success of the procedure.

PURPOSE: To identify the variables associated with the success of the XEN procedure.

PATIENTS AND METHODS: This was part of a prospective, uncontrolled, consecutive case series study. Patients with primary open-angle glaucoma or pseudo-exfoliative glaucoma were included. All the patients underwent surgical XEN implant procedure with mitomycin-C subconjunctival injection 20 minutes before surgery. Success criteria were an off-medication IOP of 6 to 16 mm Hg 12 months after surgery; no additional glaucoma surgery; no visual threatening complications, no visual acuity loss >1 Snellen line. One eye per patient was considered for statistical analysis. A univariate Cox proportional hazard regression analysis was performed to identify potential risk factors for surgical failure. Then, a multivariate Cox model was built.

RESULTS: One hundred twenty-three patients were recruited in this study: 93 patients underwent XEN implantation alone whereas 30 the combined procedure with phacoemulsification and intraocular lens implantation. Univariate Cox regression showed that the day after surgery intraocular lens>9 mm Hg was associated with surgical failure (P=0.02) and a postoperative number of needlings ≥2 in the follow-up was also predictive of surgical failure (P<0.01). These data were confirmed by a multivariate model too. At 1 year the surgical success criteria were 76% in the group with 24-hour IOP≤9 mm Hg, whereas it was 43% when above 9 mm Hg (P=0.026).

CONCLUSIONS: Our study shows that an early IOP≤9 mm Hg is predictive of the efficacy of the procedure during 1-year follow-up, whereas more than 2 needlings are predictive of failure.