Early Postoperative Intraocular Pressure is Associated With Better Pressure Control After XEN Implantation.

Cutolo Carlo A, Iester Michele, Bagnis Alessandro, Bonzano Chiara, Negri Letizia, Olivari Sara, Cappelli Francesca, Testa Valeria, Sindaco Daniele, Pizzorno Chiara, Scotto Riccardo, Saccheggiani Michela, Traverso Carlo E

СтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: PRéCIS:: Gel stent implantation is a bleb-forming surgery designed to achieve predictable pressure drop. An early low intraocular pressure (IOP) is associated with the long-term success of the procedure.

PURPOSE: To identify the variables associated with the success of the XEN procedure.

PATIENTS AND

METHODS

This was part of a prospective, uncontrolled, consecutive case series study. Patients with primary open-angle glaucoma or pseudo-exfoliative glaucoma were included. All the patients underwent surgical XEN implant procedure with mitomycin-C subconjunctival injection 20 minutes before surgery. Success criteria were an off-medication IOP of 6 to 16 mm Hg 12 months after surgery; no additional glaucoma surgery; no visual threatening complications, no visual acuity loss >1 Snellen line. One eye per patient was considered for statistical analysis. A univariate Cox proportional hazard regression analysis was performed to identify potential risk factors for surgical failure. Then, a multivariate Cox model was built.

RESULTS

One hundred twenty-three patients were recruited in this study: 93 patients underwent XEN implantation alone whereas 30 the combined procedure with phacoemulsification and intraocular lens implantation. Univariate Cox regression showed that the day after surgery intraocular lens>9 mm Hg was associated with surgical failure (P=0.02) and a postoperative number of needlings ≥2 in the follow-up was also predictive of surgical failure (P<0.01). These data were confirmed by a multivariate model too. At 1 year the surgical success criteria were 76% in the group with 24-hour IOP≤9 mm Hg, whereas it was 43% when above 9 mm Hg (P=0.026).

CONCLUSIONS

Our study shows that an early IOP≤9 mm Hg is predictive of the efficacy of the procedure during 1-year follow-up, whereas more than 2 needlings are predictive of failure.

Для цитирования: Cutolo Carlo A, Iester Michele, Bagnis Alessandro, Bonzano Chiara, Negri Letizia, Olivari Sara, Cappelli Francesca, Testa Valeria, Sindaco Daniele, Pizzorno Chiara, Scotto Riccardo, Saccheggiani Michela, Traverso Carlo E. Early Postoperative Intraocular Pressure is Associated With Better Pressure Control After XEN Implantation.. Journal of glaucoma. 2020. DOI: 10.1097/ijg.0000000000001501.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.