MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5599/admet.3437

Медицинская библиотека · ADMET & DMPK · 2026

Titanium dioxide nanoparticle-modified screen-printed electrode for erlotinib determination.

Manjulabhai Pooja Das, Mundangadan Sruthi, Paul Maria, Lal Srinivedha, Ramalal Namitha, Anto Mariya, Gangadharan Dhanya

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Erlotinib (ERL), a first-generation epidermal growth factor receptor tyrosine kinase inhibitor drug that is used in non-small cell lung cancer treatment, requires precise therapeutic drug monitoring owing to its narrow therapeutic window and significant inter-patient pharmacokinetic variability; existing chromatographic methods, while robust, are resource-intensive and incompatible with point-of-care settings, necessitating the development of simpler, cost-effective electroanalytical alternatives.

EXPERIMENTAL APPROACH: A titanium dioxide nanoparticle-modified screen-printed electrode (TiO2NP@SPE) was fabricated via a facile single-step modification and comprehensively characterized by scanning electron microscopy - energy dispersive X-ray Analysis, Fourier transform infrared spectroscopy, X-ray diffraction and electrochemical impedance spectroscopy; electrochemical performance was evaluated by cyclic voltammetry and differential pulse voltammetry, and analytical validation was performed in human serum using the standard addition method.

KEY

RESULTS

The TiO2NP@SPE demonstrated markedly enhanced electron transfer kinetics over the bare SPE, yielding a well-defined linear response with a competitive limit of detection, high sensitivity, and intra- and inter-day serum recoveries within acceptable precision limits, alongside excellent selectivity against physiologically relevant interferents and structurally related anticancer agents.

CONCLUSION

This work developed a disposable screen-printed electrode sufficient to achieve sensitive, selective, and accurate quantification of ERL in human serum using TiO2NP@SPE as a promising, clinically translatable platform for point-of-care therapeutic drug monitoring in oncology; future efforts should address the elevated detection limit relative to the bare electrode and extend validation to real patient plasma samples to fully confirm clinical applicability.

Для цитирования: Manjulabhai Pooja Das, Mundangadan Sruthi, Paul Maria, Lal Srinivedha, Ramalal Namitha, Anto Mariya, Gangadharan Dhanya. Titanium dioxide nanoparticle-modified screen-printed electrode for erlotinib determination.. ADMET & DMPK. 2026. DOI: 10.5599/admet.3437.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.