MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/embc.2013.6610365

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2013

Detection of transient, regional cardiac repolarization alternans by time-frequency analysis of synthetic electrograms.

Orini Michele, Hanson Ben, Taggart Peter, Lambiase Pier

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Repolarization alternans (RA), originating at the cellular level, is thought to produce an arrhythmogenic substrate, and surface ECG T-wave alternans (TWA) is a marker of risk for sudden cardiac death. In this paper we study RA in the unipolar electrograms (EGM), which represent the electrical activity of the heart at the tissue level. We first describe a simple analytical model to study how RA, simulated as alternating variations of action potential duration, affects EGM-TWA, and then we propose a novel methodology based on time-frequency analysis to detect EGM-TWA which occurs intermittently in few consecutive beats. In a simulation study, we used a 257-node whole heart model to reproduce several patterns of RA. RA involved specific subsets of adjacent nodes (11, 65 and 257), exhibited different amplitudes (0.25, 0.5 and 1 ms) and lasted for 40 consecutive beats of a 80-beat-long test sequence. Results show a relationship between the spatial distribution of RA and EGM-TWA: the smaller the region where RA occurs, the higher the extent of EGM-TWA. With the proposed methodology, we localized those portions of myocardium which exhibited EGM-TWA with an accuracy higher than 90%.

Для цитирования: Orini Michele, Hanson Ben, Taggart Peter, Lambiase Pier. Detection of transient, regional cardiac repolarization alternans by time-frequency analysis of synthetic electrograms.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2013. DOI: 10.1109/embc.2013.6610365.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.