Biomechanical Properties Measured With Dynamic Scheimpflug Analyzer in Myopic Maculopathy.
Аннотация
PURPOSE: Corneal biomechanical properties are associated with axial elongation. We aimed to characterize corneal biomechanical properties in highly myopic eyes with myopic maculopathy (MM).
DESIGN
Retrospective cross-sectional study.
METHODS
We included patients examined between June 2022 and August 2023 who underwent corneal visualization Scheimpflug technology (Corvis ST) measurements. MM in highly myopic eyes (axial length >26.0 mm) was evaluated using META-PM (meta-analyses of pathologic myopia) study classification based on fundus photographs with subfoveal choroidal thickness measured via spectral domain optical coherence tomography. A linear mixed model was used to analyze the association of MM features with axial length (AL) and corneal biomechanical parameters, followed by model selection using the second-order-corrected Akaike information criterion.
RESULTS
We included 189 eyes from 109 participants. A significant correlation was observed between AL and biomechanical parameters that characterize maximal corneal deformation (maximal deflection amplitude and peak distance) and stiffness parameter (stress-strain index) (P < .05). Model selection revealed that both AL and maximal deflection amplitude were independently associated with MM with category ≥2 severe, as well as with subfoveal choroidal thickness in highly myopic eyes (AL >26.0 mm).
CONCLUSIONS
In highly myopic eyes, a greater maximal deflection amplitude was identified as a risk factor for MM. Corneal biomechanical properties may serve as biomarkers for predicting the development and progression of MM.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.