MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/crd.0000000000000657

Медицинская библиотека · Cardiology in review · 2024

Innovations in Aortic Valve Replacement: A Comprehensive Overview of the Intuity Rapid Deployment Valve.

Alaklabi Abdulaziz M, Abdul Rab Saleha, Sabbah Belal N, Maklad Ahmed Essam, Dokollari Aleksander, Van den Eynde Jef, Pompeu Sa Michel, Arjomandi Rad Arian, Ahsan Muhammad Rauf, Fatehi Hassanabad Ali

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Rapid deployment/sutureless (RDS) valves have recently emerged as an innovative surgical solution, providing an alternative to traditional methods of surgical aortic valve replacement (SAVR) by eliminating the need for suture placement and tying. This innovation leads to a reduction in aortic crossclamp and cardiopulmonary bypass times, enhancing the efficiency of the procedure. Among the 2 available RDS valves, the Edwards Intuity valve in particular has been demonstrated to be a particularly promising substitute in the field of SAVR. The Intuity valve distinguishes itself from other RDS and conventional valves by yielding superior outcomes, such as a significant reduction in mortality, increase in the longevity of the valve, and a marked decrease in both mean and peak transvalvular pressure gradients. These benefits collectively contribute to its appeal as a favorable new solution. However, further investigation is needed to conclusively determine the long-term outcomes and safety of RDS valves. Nevertheless, the utilization of the Intuity valve presents an exciting solution to the existing limitations of conventional and minimally invasive SAVR, especially for patients afflicted with severe aortic stenosis.

Для цитирования: Alaklabi Abdulaziz M, Abdul Rab Saleha, Sabbah Belal N, Maklad Ahmed Essam, Dokollari Aleksander, Van den Eynde Jef, Pompeu Sa Michel, Arjomandi Rad Arian, Ahsan Muhammad Rauf, Fatehi Hassanabad Ali. Innovations in Aortic Valve Replacement: A Comprehensive Overview of the Intuity Rapid Deployment Valve.. Cardiology in review. 2024. DOI: 10.1097/crd.0000000000000657.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.