m+Medelevator.RU
← Поиск публикаций
Journal of the American College of Radiology : JACR · 2022

Utilization and Cancer Yield of Probably Benign Assessment Category in the National Mammography Database: 2009 to 2018.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Elezaby Mai A, Mao Lu, Burnside Elizabeth S, Zuley Margarita L, Berg Wendie A, Bhargavan-Chatfield Mythreyi, Lee Cindy S

Аннотация

PURPOSE: Data on utilization rate and cancer yield of BI-RADS® category 3 in routine clinical practice in diagnostic mammography are sparse. The aim of this study was to determine utilization rate and cancer yield of BI-RADS 3 in diagnostic mammography in the ACR National Mammography Database (NMD).

METHODS: Retrospective analysis of NMD mammograms from January 1, 2009, to June 30, 2018, was performed. BI-RADS 3 utilization rate in diagnostic setting was calculated and stratified by patient, facility, and examination-level variables. Patient-level cancer yield was calculated among women with BI-RADS 3 assessment and adequate follow-up (imaging follow-up ≥24 months or biopsy). Logistic regression was performed to assess the odds of utilization of BI-RADS 3, with respect to facility, examination, and patient variables, and the odds of malignancy among patients with probably benign findings. Chi-square and t tests were used to determine significance (P < .05).

RESULTS: Data from 19,443,866 mammograms from 500 NMD facilities across 31 states were analyzed, of which 3,039,952 were diagnostic mammograms. Utilization rate of BI-RADS 3 was 15.5% (470,155 of 3,039,952) in the diagnostic setting. There was a statistically significant difference in BI-RADS 3 utilization rate across all collected variables (P < .001). Patient-level cancer yield at 2-year follow-up was 0.91% (2,009 of 220,672; 95% confidence interval [CI], 0.87%-0.95%) in the diagnostic setting. Patient and examination variables associated with significantly higher likelihood of malignancy included calcifications (odds ratio, 4.27; 95% CI, 2.43-7.51), patient age > 70 years (odds ratio, 3.77; 95% CI, 2.49-5.7), and presence of prior comparisons (odds ratio, 1.23; 95% CI, 1.07-1.42).

CONCLUSIONS: In the NMD, BI-RADS 3 assessment was common in diagnostic mammography (15.5%), with an overall cancer yield of 0.91%, less than the benchmark of 2%. Utilization trends in diagnostic mammography warrant further research for optimization of use.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты