Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2023

Evaluation of four laboratory-based high-throughput SARS-CoV-2 automated antigen tests compared to RT-PCR on nasal and oropharyngeal samples.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Leineweber Thomas Daell, Ghathian Khaled, Lisby Jan Gorm, Friis-Hansen Lennart, Afzal Shoaib, Ellermann-Eriksen Svend, Ma Chih Man German, Cohen Arieh S, Jørgensen Rikke Lind, Hansen Matilde Bøgelund, Kamstrup Pia Rørbæk, Larsen Helene, Steenhard Nina, Jensen Christel Barker, Kallemose Thomas, Forsberg Maria Wendelboe, Kirkby Nikolai Søren, Schneider Uffe Vest

Аннотация

BACKGROUND: The demand for RT-PCR testing has been unprecedented during the SARS-CoV-2 pandemic. Fully automated antigen tests (AAT) are less cumbersome than RT-PCR, but data on performance compared to RT-PCR are scarce.

METHODS: The study consists of two parts. A retrospective analytical part, comparing the performance of four different AAT on 100 negative and 204 RT-PCR positive deep oropharyngeal samples divided into four groups based on RT-PCR cycle of quantification levels. In the prospective clinical part, 206 individuals positive for and 199 individuals negative for SARS-CoV-2 were sampled from either the anterior nasal cavity (mid-turbinate) or by deep oropharyngeal swabs or both. The performance of AATs was compared to RT-PCR.

RESULTS: The overall analytical sensitivity of the AATs differed significantly from 42% (95% CI 35-49) to 60% (95% CI 53-67) with 100% analytical specificity. Clinical sensitivity of the AATs differed significantly from 26% (95% CI 20-32) to 88% (95% CI 84-93) with significant higher sensitivity for mid-turbinate nasal swabs compared to deep oropharyngeal swabs. Clinical specificity varied from 97% to 100%.

CONCLUSION: All AATs were highly specific for detection of SARS-CoV-2. Three of the four AATs were significantly more sensitive than the fourth AAT both in terms of analytical and clinical sensitivity. Anatomical test location significantly influenced the clinical sensitivity of AATs.