DOI 10.1097/md.0000000000025365
Clinical study of combined application of indocyanine green and methylene blue for sentinel lymph node biopsy in breast cancer.
Аннотация
OBJECTIVE
This study aims to investigate the feasibility of combined application of indocyanine green (ICG) and methylene blue (MB) for sentinel lymph node biopsy (SLNB) in patients with early breast cancer.
METHODS
A total of 415 patients who underwent SLNB and axillary lymph node dissection were enrolled. Sentinel lymph node (SLN) was assessed in 197 patients with ICG and MB combination method, while, the other 218 patients were detected by MB method alone. During surgery, all SLNs were harvested for pathological examination. Then the detection rate and false negative rate of SLNs were comparatively analyzed between the 2 groups.
RESULTS
In the combined ICG and MB group, the detection rate of SLNs was 96.9%, significantly higher than that of MB group, which was 89.7% (P < .05). Similarly, in combined group, the average number of SLNs per patient was 3.0, much higher than that of MB group, which was 2.1 (P < .05). There was no statistically significant difference in false negative rate between combined group and MB alone group, which was 7.3% and 10.5%, respectively (P = .791).
CONCLUSION
The combined application of ICG and MB for SLNB is much more effective than MB alone in detecting SLNs.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.