MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm14176323

Медицинская библиотека · Journal of clinical medicine · 2025

Evaluation of Maxillary Molar Distalization Supported by Mini-Implants with the Advanced Molar Distalization Appliance (amda®): Preliminary Results of a Prospective Clinical Trial.

Karvelas Nikolaos, Samandara Aikaterini, Dragomir Bogdan Radu, Chehab Alice, Panaite Tinela, Romanec Cristian, Papadopoulos Moschos A, Zetu Irina Nicoleta

СтатьяПеревод пока не подготовлен

Аннотация

Background

Class II is considered one of the most common malocclusions, influencing 37% of schoolchildren in Europe and 33% of orthodontic patients in the United States. When this type of malocclusion is combined with increased overjet with proclined teeth and maxillary excess, then moving maxillary molars distally is suggested. According to the recent literature, modern appliances that lack patient cooperation can be combined with temporary anchorage devices to provide absolute and skeletal anchorage while supporting the non-compliance appliances to eliminate their side effects, such as anterior and posterior anchorage loss along with maxillary molar inclination and rotation. To counteract these limitations, the Advanced Molar Distalization Appliance (amda®), a non-compliance appliance for maxillary molar distalization supported by two mini-implants (MIs) with anterior abutments, was recently developed.

Methods

In this preliminary prospective clinical trial, eight consecutive patients treated with the amda® are evaluated through lateral cephalometric radiographs, while its application, construction, and anchorage is presented and discussed. The evaluation of dentoalveolar and skeletal changes has been made with 14 variables measured on the pre- and post-cephalometric radiographs before and immediately after maxillary molar distalization (T0 and T1, respectively), along with cephalometric superimpositions by the structural method.

Results

In total, the mean distal molar movement was 4.2 ± 1.37 mm, the mean distal tipping was 1.7 ± 1.9 degrees, and the vertical movement was 1.6 ± 2.6 mm.

Conclusions

The amda® seems to provide an ideal option for treating patients with Class II malocclusion, achieving bodily movement of the maxillary molars with only minimal distal tipping and no anchorage loss.

Для цитирования: Karvelas Nikolaos, Samandara Aikaterini, Dragomir Bogdan Radu, Chehab Alice, Panaite Tinela, Romanec Cristian, Papadopoulos Moschos A, Zetu Irina Nicoleta. Evaluation of Maxillary Molar Distalization Supported by Mini-Implants with the Advanced Molar Distalization Appliance (amda®): Preliminary Results of a Prospective Clinical Trial.. Journal of clinical medicine. 2025. DOI: 10.3390/jcm14176323.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.