DOI 10.1111/j.1552-6569.2009.00445.x
Three-dimensional digital subtraction angiography in evaluation of vertebro-basilar artery dissections: comparison with 2D DSA.
Аннотация
BACKGROUND AND PURPOSE: The purpose of this study was to clarify characteristic findings on three-dimensional (3D) digital subtraction angiography (DSA), and to investigate diagnostic usefulness of 3D DSA in vertebro-basilar dissections (VBD).
METHODS
In 25 consecutive patients with VBD, two-dimensional (2D) DSA, and 3D DSA findings were evaluated by a scoring system. The effects of 3D DSA results on diagnosis were scored in comparison with 2D DSA results.
RESULTS
A proximal stenosis, a distal stenosis, a bleb, and a relationship between the posterior inferior cerebellar artery and the dissection were significantly better visualized in 3D DSA than those in 2D DSA (P < .05). A characteristic finding of VBD on 3D DSA was a combination of an aneurysmal bulging and its proximal and distal stenoses, which was observed in 92% of the 25 patients.
CONCLUSIONS
Three-dimensional DSA was more useful for diagnosis in patients with VBD in comparison with 2D DSA.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.