Comparison of test performance characteristics of MRI, MR angiography, and CT angiography in the diagnosis of carotid and vertebral artery dissection: a review of the medical literature.

Provenzale James M, Sarikaya Basar

Сравнительное исследованиеОценочное исследованиеСтатьяОбзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

Initial assessment of patients with suspected dissection of the carotid or vertebral arteries typically is made by MRI, alone or in combination with MR angiography (MRA) or CT angiography (CTA). We reviewed the medical literature to determine, based on test performance characteristics such as sensitivity, specificity, positive predictive value, and negative predictive value, whether evidence could be found to support routine use of one imaging technique over the other for assessment of suspected dissection.

CONCLUSION

Test characteristics for MR techniques such as MRI and MRA were relatively similar to those for CTA in diagnosis of carotid and vertebral artery dissection.

Для цитирования: Provenzale James M, Sarikaya Basar. Comparison of test performance characteristics of MRI, MR angiography, and CT angiography in the diagnosis of carotid and vertebral artery dissection: a review of the medical literature.. AJR. American journal of roentgenology. 2009. DOI: 10.2214/ajr.08.1688.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.