MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jiph.2025.102845

Медицинская библиотека · Journal of infection and public health · 2025

RPA-CRISPR/Cas12a detection based on HCMV-UL123 gene: A way with higher detection rate than clinical detection methods.

Liu Tianyang, Wang Yao, Liao Zihao, Li Xiaowen, Tang Shanshan, Zhang Zhongming, Chu Ming, Wei Lanlan

СтатьяОценочное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Human cytomegalovirus (HCMV), a prevalent double-stranded DNA enveloped virus, poses a threat to immunocompromised individuals. The current clinical detection methods are insufficient in sensitivity, highlighting the need for more effective approaches.

METHODS

We designed and screened RPA primers and crRNA based on the UL123 gene of HCMV. Evaluate the HCMV-RPA-CRISPR detection method using cloned plasmids and the whole-genome samples of HCMV-infected cells. Conduct RPA-CRISPR/Cas12a reactions with 48 clinical samples and compare the results with those of PCR-Fluorescent Probe Method in clinical applications and the qPCR method for detecting the UL123 gene.

RESULTS

The optimized RPA-CRISPR system exhibited high sensitivity and specificity for HCMV detection. The positive rate of clinical sample detection was approximately 20.5 % (6/48) higher than that of the clinical detection method.

CONCLUSION

Currently, the sensitivity and early detection of HCMV in clinical settings are still limited. The UL123 gene of HCMV is characterized by high transcription in the early stage and high conservation. The RPA-CRISPR/Cas12a technology exhibits high sensitivity in detecting the HCMV UL123 gene, and it is expected to provide a more effective method for the early specific detection of HCMV infection.

Для цитирования: Liu Tianyang, Wang Yao, Liao Zihao, Li Xiaowen, Tang Shanshan, Zhang Zhongming, Chu Ming, Wei Lanlan. RPA-CRISPR/Cas12a detection based on HCMV-UL123 gene: A way with higher detection rate than clinical detection methods.. Journal of infection and public health. 2025. DOI: 10.1016/j.jiph.2025.102845.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.