MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/09553000903043059

Медицинская библиотека · International journal of radiation biology · 2009

Comparing oxygen-sensitive MRI (BOLD R2*) with oxygen electrode measurements: a pilot study in men with prostate cancer.

Chopra Supriya, Foltz Warren D, Milosevic Michael F, Toi Ants, Bristow Robert G, Ménard Cynthia, Haider Masoom A

Клиническое исследованиеСравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the relationship between oxygen-sensitive Magnetic Resonance Imaging (MRI) and oxygen measurements in prostate cancer.

METHODS

Nine men underwent MRI examinations followed by needle oxygen measurements of tumor bearing region within prostate gland and five men further consented to biopsy. Median pO2 and hypoxic fraction < 5 mm Hg (HP5) were derived. Biopsies were immunostained for Carbonic Anhydrase IX (CA IX), Hypoxia Inducible Factor-1 (HIF 1) and Glucose Transporter-1 (GLUT 1). Corresponding Regions-of-Interest (ROI) were delineated on T2-weighted (T2w) MRI by two observers. Median R2* was calculated for each ROI. Spearman correlation was calculated between R2* and HP5/pO2.

RESULTS

MRI quality evaluation resulted in exclusion of 4/18 ROI due to motion (n = 2) and rectal air susceptibility artifact (n = 2). Quality of remaining data was validated by concordance of R2* with T2w, indices and with secondary observer R2* (r = 0.94, p = 0.005). Correlation was observed between R2* and HP5 (r = 0.76, p = 0.02) and a trend was noted between R2* and pO2 (r = -0.66, p = 0.07). GLUT 1 and HIF 1 were expressed in all patients, and CA IX was expressed in one patient with high HP5 (77%) and low pO2 (1.4 mm Hg).

CONCLUSIONS

MRI using R2* quantification is a promising tool for non-invasive imaging of prostate cancer hypoxia.

Для цитирования: Chopra Supriya, Foltz Warren D, Milosevic Michael F, Toi Ants, Bristow Robert G, Ménard Cynthia, Haider Masoom A. Comparing oxygen-sensitive MRI (BOLD R2*) with oxygen electrode measurements: a pilot study in men with prostate cancer.. International journal of radiation biology. 2009. DOI: 10.1080/09553000903043059.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.