MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3349/ymj.2007.48.4.678

Медицинская библиотека · Yonsei medical journal · 2007

Accuracy of a high prostate-specific antigen level for prostate cancer diagnosis upon initial biopsy in Korean men.

Shim Hong Bang, Lee Sang Eun, Park Hyoung Keun, Ku Ja Hyeon

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study aimed to evaluate the cancer detection rate in a Korean population with prostate-specific antigen (PSA) levels greater than or equal to 20.0 ng/mL.

MATERIALS AND

METHODS

A total of 174 men 50 to 79 years old (median 69) included in the study. The median prostate volume of the patients was 44.8 mL (range 14.1 to 210.0) and their serum PSA ranged from 20.0 to 9725.0 ng/mL (median 44.8).

RESULTS

Of 174 men 141 (81.0%) were diagnosed with prostate cancer on initial biopsy. In the total number of patients, the positive predictive value (PPV) was 62.9% for PSA 20 to 29.9, 72.7% for PSA 30 to 39.9 and 100% for PSA 40 to 49.9 ng/mL. In patients with an abnormal digital rectal examination (DRE), the values for these PSA ranges increased to 89.5%, 91.7% and 100%, respectively. The PPV was 81.0% for PSA cutoff of 20, 89.2% for a cutoff of 30, 95.4% for a cutoff of 40, and 94.7% for a cutoff of 50 ng/mL. In conjunction with an abnormal DRE, the values for these PSA cutoffs increased to 95.9%, 98.1%, 100%, and 100%, respectively.

CONCLUSION

Our data suggest the ability to predict the presence of prostate cancer reliably on initial biopsy when PSA threshold is greater than or equal to 50 ng/mL. This PSA threshold may be lowered to 40 ng/mL in the presence of an abnormal DRE. In Korean men with high PSA, the detection rate of prostate cancer on biopsy appears to be comparable to that for American men.

Для цитирования: Shim Hong Bang, Lee Sang Eun, Park Hyoung Keun, Ku Ja Hyeon. Accuracy of a high prostate-specific antigen level for prostate cancer diagnosis upon initial biopsy in Korean men.. Yonsei medical journal. 2007. DOI: 10.3349/ymj.2007.48.4.678.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.