MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0022-5347(05)64543-0

Медицинская библиотека · The Journal of urology · 2002

Robustness of free prostate specific antigen measurements to reduce unnecessary biopsies in the 2.6 to 4.0 ng./ml. range.

Roehl Kimberly A, Antenor Jo Ann V, Catalona William J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Prostate specific antigen (PSA) cutoffs lower than 4.0 ng./ml. are being evaluated more frequently but lower PSA cutoffs increase the number of prostatic biopsies. PSA exists in several forms free and complexed to proteins. Percent free PSA is lower in men with prostate cancer. Accordingly, free PSA and complexed PSA have been used to distinguish between cancer and benign disease in the diagnostic gray zone of 4 to 10 ng./ml. to eliminate unnecessary biopsies. There are limited data on the robustness of free PSA measurements in the 2.6 to 4.0 ng./ml. total PSA range.

MATERIALS AND

METHODS

We evaluated percent free PSA measurements to discriminate between cancer and benign conditions in 965 consecutive volunteers in a prostate cancer screening study who underwent prostatic biopsy for a PSA of 2.6 to 4.0 ng./ml. and had benign digital rectal examination.

RESULTS

Overall 25% of men had cancer detected. A 25% free PSA cutoff detected 85% of cancers and avoided 19% of negative (cancer-free) biopsies, while a 30% free PSA cutoff detected 93% of cancers and avoided only 9% of negative biopsies. Of those men who underwent radical prostatectomy 132 (80%) had pathologically organ confined tumors. Only 5% of these tumors fulfilled the published pathological criteria for possibly clinically unimportant tumors.

CONCLUSIONS

Percent free PSA provides risk assessment but does not eliminate many unnecessary prostatic biopsies while maintaining a high sensitivity in the narrow total PSA range of 2.6 to 4.0 ng./ml.

Для цитирования: Roehl Kimberly A, Antenor Jo Ann V, Catalona William J. Robustness of free prostate specific antigen measurements to reduce unnecessary biopsies in the 2.6 to 4.0 ng./ml. range.. The Journal of urology. 2002. DOI: 10.1016/s0022-5347(05)64543-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.