Annals of translational medicine · 2021
A four-year observation of corneal densitometry after implantable collamer lens V4c implantation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhao Jing, Yang Wen, Zhao Jiao, Shen Yang, Sun Ling, Han Tian, Wang Xiaoying, Yao Peijun, Zhou Xingtao
Аннотация
BACKGROUND: To observe the changes in corneal densitometry (CD) with a Pentacam after implantable collamer lens (ICL) V4c implantation in myopia patients, and to investigate potential influencing factors.
METHODS: We reviewed 65 eyes of 33 patients (mean age, 29.08±5.54 years) with myopia or myopic astigmatism who underwent ICL V4c implantation. Clinic parameters and Pentacam images of corneal topography and CD were obtained pre- and postoperatively.
RESULTS: After an average of 52±2.2 months follow-up, the efficacy and safety indexes assessed at the last follow-up were 1.03±0.18 and 1.21±0.21, respectively. Except in the central annular zone of 0-2 mm, the CD values increased significantly at postoperative day 1 and decreased significantly until postoperative 1 year (P<0.05). The increase in CD values at different annular zones at postoperative day 1 was ranked as: 0-2 mm <2-6 mm < 6-10 mm. No significant difference was observed in corneal density at 1 week, 1 month, and 1-year follow-up when compared with the preoperative value (P>0.05). The CD value at 4 years follow-up increased significantly and correlated positively with age and preoperative uncorrected distance visual acuity, and negatively with preoperative spherical equivalent and intraocular pressure (IOP) (P<0.05).
CONCLUSIONS: ICL V4c implantation demonstrated safety and efficacy for myopia correction. The CD value increased at 4 years postoperatively and correlated with age, preoperative spherical equivalent, uncorrected distance visual acuity, and IOP.
METHODS: We reviewed 65 eyes of 33 patients (mean age, 29.08±5.54 years) with myopia or myopic astigmatism who underwent ICL V4c implantation. Clinic parameters and Pentacam images of corneal topography and CD were obtained pre- and postoperatively.
RESULTS: After an average of 52±2.2 months follow-up, the efficacy and safety indexes assessed at the last follow-up were 1.03±0.18 and 1.21±0.21, respectively. Except in the central annular zone of 0-2 mm, the CD values increased significantly at postoperative day 1 and decreased significantly until postoperative 1 year (P<0.05). The increase in CD values at different annular zones at postoperative day 1 was ranked as: 0-2 mm <2-6 mm < 6-10 mm. No significant difference was observed in corneal density at 1 week, 1 month, and 1-year follow-up when compared with the preoperative value (P>0.05). The CD value at 4 years follow-up increased significantly and correlated positively with age and preoperative uncorrected distance visual acuity, and negatively with preoperative spherical equivalent and intraocular pressure (IOP) (P<0.05).
CONCLUSIONS: ICL V4c implantation demonstrated safety and efficacy for myopia correction. The CD value increased at 4 years postoperatively and correlated with age, preoperative spherical equivalent, uncorrected distance visual acuity, and IOP.