MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/atm-20-6628

Медицинская библиотека · Annals of translational medicine · 2021

A four-year observation of corneal densitometry after implantable collamer lens V4c implantation.

Zhao Jing, Yang Wen, Zhao Jiao, Shen Yang, Sun Ling, Han Tian, Wang Xiaoying, Yao Peijun, Zhou Xingtao

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To observe the changes in corneal densitometry (CD) with a Pentacam after implantable collamer lens (ICL) V4c implantation in myopia patients, and to investigate potential influencing factors.

METHODS

We reviewed 65 eyes of 33 patients (mean age, 29.08±5.54 years) with myopia or myopic astigmatism who underwent ICL V4c implantation. Clinic parameters and Pentacam images of corneal topography and CD were obtained pre- and postoperatively.

RESULTS

After an average of 52±2.2 months follow-up, the efficacy and safety indexes assessed at the last follow-up were 1.03±0.18 and 1.21±0.21, respectively. Except in the central annular zone of 0-2 mm, the CD values increased significantly at postoperative day 1 and decreased significantly until postoperative 1 year (P<0.05). The increase in CD values at different annular zones at postoperative day 1 was ranked as: 0-2 mm <2-6 mm < 6-10 mm. No significant difference was observed in corneal density at 1 week, 1 month, and 1-year follow-up when compared with the preoperative value (P>0.05). The CD value at 4 years follow-up increased significantly and correlated positively with age and preoperative uncorrected distance visual acuity, and negatively with preoperative spherical equivalent and intraocular pressure (IOP) (P<0.05).

CONCLUSIONS

ICL V4c implantation demonstrated safety and efficacy for myopia correction. The CD value increased at 4 years postoperatively and correlated with age, preoperative spherical equivalent, uncorrected distance visual acuity, and IOP.

Для цитирования: Zhao Jing, Yang Wen, Zhao Jiao, Shen Yang, Sun Ling, Han Tian, Wang Xiaoying, Yao Peijun, Zhou Xingtao. A four-year observation of corneal densitometry after implantable collamer lens V4c implantation.. Annals of translational medicine. 2021. DOI: 10.21037/atm-20-6628.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.