The influence of routine uncomplicated phacoemulsification on the orthogonality of the cornea.

Tutchenko Larysa, Patel Sudi, Voytsekhivskyy Oleksiy, Skovron Mykhailo, Horak Olha

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to determine the effect of routine uncomplicated phacoemulsification on the orthogonal distribution of mass within the central optical zone of the cornea.

METHODS

Astigmatism at both corneal surfaces was evaluated using Orbscan II (Bausch &and Lomb) before and up to 3 months after routine phacoemulsification (one eye/patient). The data were subjected to vector analysis to estimate the pre-and postoperative total astigmatism of the cornea (TCA).

RESULTS

Reporting the chief findings in minus cylinder (diopters, DC) over the central 3 mm (A) and 5 mm (B) optical zones. Mean TCA powers (±sd) at pre- and 3-months postop were A) -4.45DC (±2.00) and -5.69DC (±2.69), B) -2.91DC (±2.22) and -2.71DC (±1.60). Change in mean power was significant over 3 mm (P < 0.01, n = 49) but not over 5 mm. Inter-zonal differences were significant (P < 0.01). There was a significant linear relationship between the change in TCA power (y = preoperative-postoperative) and TCA at preoperative stage (x) where, A) y = 0.45x + 3.12 (r = 0.336, n = 49, P = 0.018), B) y = x + 2.65 (r = 0.753, n = 49, P = <0.01). Over the central 3 mm zone only, change (preoperative-postoperative) in axis (°) of TCA (y1) was significantly associated with TCA axis at preoperative stage (x1) where y1 = 1.391x1-0.008x12-0.701 (r = 0.635, n = 49, P < 0.01).

CONCLUSION

Changes in TCA power and axis at 3 months postop, determined using Orbscan II, are indicative of orthogonal alterations in the distribution of corneal tissue. Over the central 3 mm zone, the association between y1 and x1 shows that a change in TCA axis is more profound when preoperative axis is near 90° i.e., against-the-rule.

Для цитирования: Tutchenko Larysa, Patel Sudi, Voytsekhivskyy Oleksiy, Skovron Mykhailo, Horak Olha. The influence of routine uncomplicated phacoemulsification on the orthogonality of the cornea.. Indian journal of ophthalmology. 2021. DOI: 10.4103/ijo.ijo_1168_20.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.