Cano-Ortiz Antonio, Sánchez-Ventosa Álvaro, Membrillo Alberto, Castillo Rosa, Gomera Aurora, López-Pérez María Dolores, Villarrubia Alberto

Аннотация

PURPOSE: To analyze the target induced astigmatism (TIA), surgically induced astigmatism (SIA), difference vector (DV), and correction index (CI) in the correction of astigmatism with phakic lenses, and its influence on visual acuity, and to analyze the safety and efficacy indexes of the correction of high and low power astigmatism with toric phakic lenses.

DESIGN: Retrospective comparative study.

METHODS: The medical records of patients that were operated on at the research center during the period were analyzed. Results were divided into Low Astigmatism Group - LAG (33 eyes) and High Astigmatism Group - HAG (93 eyes) according to the implanted toric ICL lens power. Preoperative refraction and resultant postoperative refraction were analyzed by vector analysis. Visual acuity pre and postop, with and without optical correction, were compared.

RESULTS: A total of 126 eyes were studied. The average preop refraction was -5.02 D sphere with -2.61 D cylinder. The average ICL lens power implanted was -8.31 D sphere +2.77 D cylinder. Refractive remaining was -0.01 ± 0.11 D sphere -0.15 ± 0.28 D cylinder. The arithmetic average angle of error in the astigmatism correction was 1.08°. The resultant cylinder was -0.03 ± 0.12 D and -0.19 ± 0.30 D in the low and high astigmatism groups, respectively, with a mean UDVA -0.01 ± 0.10 and 0.01 ± 0.16 and CDVA -0.03 ± 0.08 and -0.01 ± 0.17 for each group. The safety and efficacy indexes for the low astigmatism group were 1.09 ± 0.16 and 1.05 ± 0.17, respectively, with 1.11 ± 0.17 and 1.06 ± 0.16 for the high astigmatism group.

CONCLUSIONS: The correction of astigmatism by the implantation of toric phakic lenses of the posterior chamber is safe and effective, independently of the amount of cylinder corrected.