Analysis of biometric parameters of 2340 eyes measured with optical biometer Lenstar LS900 in a Caucasian population.

Popov Ivajlo, Waczulikova Iveta, Stefanickova Jana, Valaskova Jela, Tomcikova Dana, Shiwani Haaris A, Delev Delian, Rodrigo Luis, Saxena Sandeep, Kruzliak Peter, Krasnik Vladimir

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To describe the pattern and mutual relationships between basic biometric characteristics of the eye in a Central European Caucasian population.

METHODS

A single-centre retrospective study of 2340 patients (965 males, 1375 females) scheduled for cataract surgery between 2014 and 2016. Measurements using laser interferometry included AL (axial length), K (average corneal curvature), ACD (anterior chamber depth), LT (lens thickness), CCT (central corneal thickness), AST (astigmatism) and WTW (white to white). Subjects were stratified by gender and controlled for age. Descriptive, correlation and regression analyses were performed on the data.

RESULTS

The mean AL was 23.33 ± 1.01 mm - higher in males (23.59 ± 0.99 mm), in comparison to females (23.15 ± 0.99 mm). The elderly had lower ACD and higher LT, while males had higher AL independent of age. Furthermore, LT and K decreased with AL, while ACD decreased with LT and increased with AL independent of age and gender.

CONCLUSIONS

The estimates of the biometrics are obtained on a large sample of subjects and can serve as normative values for Lenstar LS900 in the Central European Caucasian population.

Для цитирования: Popov Ivajlo, Waczulikova Iveta, Stefanickova Jana, Valaskova Jela, Tomcikova Dana, Shiwani Haaris A, Delev Delian, Rodrigo Luis, Saxena Sandeep, Kruzliak Peter, Krasnik Vladimir. Analysis of biometric parameters of 2340 eyes measured with optical biometer Lenstar LS900 in a Caucasian population.. European journal of ophthalmology. 2021. DOI: 10.1177/1120672121998920.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.