PURPOSE: To determine the effect of upper blepharoplasty on corneal topography and intraocular lens power calculation using Galilei and IOLMaster.
METHODS
Thirty patients submitted to upper blepharoplasty from May 2014 to March 2017 at the Hospital Oftalmológico de Sorocaba (São Paulo, Brazil) were included in this observational case series. All patients underwent imaging sessions with Galilei and IOLMaster preoperatively (baseline) and at 1 and 6 months postoperatively. Primary outcome measures using both devices included flattest, average, and steepest corneal curvature, corneal astigmatism, and blepharoplasty-induced corneal astigmatism. Determination of axial length and lens power calculation were performed using only IOLMaster (Holladay formula). Paired t-test and vectorial analysis were used for statistical analysis.
RESULTS
Sixty eyes from 30 patients were prospectively included. Vectorial analysis showed that 6 months after surgery, blepharoplasty induced on average 0.39 D and 0.31 D of corneal astigmatism, as measured with Galilei and IOLMaster, respectively. IOLMaster measurements showed that average corneal curvature (44.56 vs 44.64 D, p=0.01), steepest corneal curvature (45.17 vs 45.31, p=0.01) and corneal astigmatism (1.22 vs 1.34, p=0.03) were higher 6 months after surgery. IOLMaster measurements also showed that intraocular lens power was significantly smaller 6 months after surgery (22.07 vs 21.93, p=0.004). All other parameters showed no change for comparisons between baseline and 6 months (p>0.05 for all comparisons).
CONCLUSION
Upper eyelid blepharoplasty influenced intraocular lens calculation using the IOLMaster. However, the influence was not clinically significant. No topographic changes were found using Galilei.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.