MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aos.14720

Медицинская библиотека · Acta ophthalmologica · 2020

Consecutive contralateral comparison of toric and non-toric implantable collamer lenses V4c in vault after implantation for myopia and astigmatism.

Zhao Jiao, Zhao Jing, Yang Wen, Li Meiyan, Hao Gengsheng, Chen Zhuoyi, Wang Xiaoying, Yao Peijun, Zhou Xingtao

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: To compare the vault performance between implantable collamer lens (ICL) V4c and Toric ICL (TICL) V4c after implantation and to investigate the affecting factors.

METHODS

Sixty-eight eyes from 34 patients with myopia or myopia astigmatism who underwent implantation of TICL in one eye (group A) and identically sized ICL (group B) in the contralateral eye were included. Mean follow-up time were 7.58 ± 1.63 months (range: 6-10 months). Vault was compared between the two groups and correlations between vault and age, preoperative ocular biometric measurements were analysed. Generalized estimating equation (GEE) model of postoperative vault adjusting for within-patient intereye correlations was performed.

RESULTS

The safety indices were 1.27 and 1.35, and the efficacy indices were 1.20 and 1.24 for groups A and B, respectively. Vault of TICL was significantly higher than that of ICL (554.11 ± 219.36 μm vs 449.70 ± 172.47 μm, P < 0.001). The difference between ICL/TICL size and WTW (size-WTW) and STS (size-STS), anterior chamber depth and pupil diameter (PD) were positively correlated with vault. Patient age and clear lens rise measured by Pentacam were negatively correlated with vault. Results of GEE model showed preoperative PD, age, cylindrical power of TICL and size-WTW were influencing factors for postoperative vault.

CONCLUSIONS

Vault after TICL implantation is higher than that with ICL. PD, age, cylindrical power of TICL and size-WTW could affect postoperative vault.

Для цитирования: Zhao Jiao, Zhao Jing, Yang Wen, Li Meiyan, Hao Gengsheng, Chen Zhuoyi, Wang Xiaoying, Yao Peijun, Zhou Xingtao. Consecutive contralateral comparison of toric and non-toric implantable collamer lenses V4c in vault after implantation for myopia and astigmatism.. Acta ophthalmologica. 2020. DOI: 10.1111/aos.14720.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.