DOI 10.1016/j.jacep.2020.05.012
Para-Hisian Pacing During Sinus Rhythm: Establishing Threshold Values to Distinguish Nodal From Septal Pathway Conduction.
Аннотация
OBJECTIVES
This study sought to identify minimum threshold values below which conduction over the atrioventricular (AV) node would be unexpected.
BACKGROUND
Para-Hisian pacing is used to evaluate for the presence of a septal accessory pathway (AP); however, threshold values to differentiate nodal from AP conduction are unknown.
METHODS
The authors performed high- and low-output para-Hisian pacing during sinus rhythm to capture the His and para-Hisian ventricular myocardium (H+V) and para-Hisian ventricular myocardium (V) alone, respectively. The change in stimulation (stim)-to-atrial electrogram interval after loss of His bundle capture in patients with (AP+) and without (AP-) a septal AP was evaluated. Stim-to-proximal coronary sinus (PCS) and stim-to-high right atrium (HRA) intervals were measured and within-patient differences (△) for V and H+V capture were calculated.
RESULTS
A total of 23 AP+ and 45 AP- patients were evaluated. The difference in stimulus to earliest atrial signal in the high right atrial catheter seen with the loss of His bundle capture (△-stim-HRA) (21 ms; interquartile range [IQR]: 3 to 43 ms vs. 64 ms; IQR: 56 to 73 ms; p < 0.001) and difference in stimulus to earliest atrial signal in the proximal coronary sinus catheter seen with the loss of His Bundle capture (△-stim-PCS) (11 ms; IQR: 0 to 30 ms vs. 61 ms; IQR: 52 to 72 ms; p < 0.001) were shorter in AP+ patients. The shortest △-stim-PCS and △-stim-HRA in AP- patients were 37 ms and 32 ms, respectively, whereas the longest corresponding intervals in AP+ patients were 51 ms and 75 ms, respectively.
CONCLUSIONS
A △-stim-PCS <37 ms or △-stim-HRA <32 ms confirmed the presence of a septal AP, whereas a value >51 ms for △-stim-PCS or >75 ms for △-stim-HRA excluded it. Alternatively, the minimum △-stim-PCS with loss of His capture compatible with AV nodal conduction in isolation was 37 ms, and a △-stim-PCS >51 ms effectively ruled out the presence of a septal AP.