Investigative radiology · 2012

Diagnostic accuracy of dynamic computed tomographic angiographic of the lower leg in patients with critical limb ischemia.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sommer Wieland H, Bamberg Fabian, Johnson Thorsten R C, Weidenhagen Rolf, Notohamiprodjo Mike, Schwarz Florian, Reiser Maximilian F, Nikolaou Konstantin

Аннотация

OBJECTIVE: The purpose of this study was to assess the diagnostic accuracy of dynamic computed tomographic angiography (dyn-CTA) in patients with critical lower leg ischemia.

MATERIALS AND METHODS: A population of 29 patients with known peripheral arterial occlusive disease (Fontaine stage III or IV) was examined with a combined CTA protocol consisting of a standard CTA (s-CTA) of the lower leg runoff from the diaphragm to the toes and dyn-CTA of the calves (scan range, 48 cm; 8 phases; 3.5 seconds per phase, 100 kV; 120 mAs; contrast volume, 50 mL; flow rate, 5.0 mL/s). Digital subtraction angiography was performed on all patients and served as a reference standard. For each of seven lower leg artery segments, arterial contrast and diagnostic confidence for stenosis assessment (3-point scale) were tested for s-CTA and dyn-CTA. Similarly, stenoses of calf-segments were classified on a 3-point scale separately for s-CTA and dyn-CTA and were compared with digital subtraction angiography to assess diagnostic accuracy.

RESULTS: Compared with s-CTA, dyn-CTA resulted in significantly higher arterial contrast enhancement (68% vs 46% optimal contrast; P < 0.01) and higher diagnostic confidence (64% vs 48% fully confident, respectively, P < 0.05). Dyn-CTA had a slightly higher sensitivity for the detection of significant stenosis (98.0% vs 96.6%), and for the detection of occlusion (95.4% vs 94.4%). Specificity for dyn-CTA was higher than for s-CTA, both for detection of stenosis (97.1% vs 92.2%) and especially for the detection of vessel occlusions (99.3% vs 94.4%; P < 0.05).

CONCLUSIONS: Compared with s-CTA, dyn-CTA provides improved arterial contrast enhancement, higher diagnostic confidence, and increased diagnostic accuracy for the detection of stenoses and occlusions in peripheral arterial occlusive disease patients.