Utility of Inferior Lead Q-waveforms in diagnosing Ventricular Tachycardia.
Аннотация
BACKGROUND
Electrocardiogram (ECG) differentiation of wide complex tachycardia (WCT) into ventricular tachycardia (VT) and supraventricular tachycardia with aberration (SVT-A) is often challenging.
OBJECTIVE
To determine if the presence of Q-waveforms (QS, Qr, QRs) in the inferior leads (II, III, aVF) can differentiate VT from SVT-A in a WCT compared to Brugada algorithm. We studied 2 inferior lead criteria namely QWC-A where all the inferior leads had a similar Q wave pattern and QWC-B where only lead aVF had a Q-waveform.
METHODS
A total of 181 consecutive cases of WCT were identified, digitally separated into precordial leads and inferior leads and independently reviewed by 2 electrophysiologists. An electrocardiographic diagnosis of VT or SVT-A was assigned based on Brugada and inferior lead algorithms. Results were compared to the final clinical diagnosis.
RESULTS
VT was the final clinical diagnosis in 24.9% of ECG cohort (45/181); 75.1% (136/181) were SVT-A. QWC-A and QWC-B had a high specificity (93.3% and 82.8%) and accuracy (78.2% and 71.0%), but low sensitivity (33.3% and 35.6%) in differentiating VT from SVT-A. The Brugada algorithm yielded a sensitivity of 82.2% and specificity of 68.4%. Area under the curve in ROC analysis was highest with Brugada algorithm (0.75, 95% CI 0.69-0.81) followed by QWC-A (0.63, 95% CI 0.56-0.70) and QWC-B (0.59, 95% CI 0.52-0.67).
CONCLUSION
QWC-A and QWC-B criteria had poor sensitivity but high specificity in diagnosing VT in patients presenting with WCT. Further research combining this simple criterion with other newer diagnostic algorithms can potentially improve the accuracy of the overall diagnostic algorithm.