Simple differential entrainment screens ablation strategy for slow-fast atrioventricular nodal reentrant tachycardia.

Iizuka Takashi, Nakajima Tadashi, Tamura Shuntaro, Hasegawa Hiroshi, Kobari Takashi, Nakahara Shiro, Kurabayashi Masahiko, Kaneko Yoshiaki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Ablation of slow-fast atrioventricular nodal reentrant tachycardia (S/F-AVNRT) is occasionally refractory. We hypothesized that the site of ablation for curing S/F-AVNRT can be screened by simple differential atrial entrainment pacing (EP) from the high right atrium (HRA) and proximal coronary sinus (prox-CS).

METHODS

We enrolled 43 patients with S/F-AVNRT who underwent successful differential atrial EP followed by successful ablation of slow pathway (SP) using step-wise approach, and compared the atrio-His (A-H) interval at the recording of His bundle immediately after EP from the HRA [A-H(HRA)], with the interval between atrial deflection at the prox-CS and His bundle electrogram after EP at an identical cycle length from the prox-CS [A-H (prox-CS)].

RESULTS

A typical A-H(CS) shorter than A-H(HRA), consistent with typical SP conduction, was observed in 39 patients (91%), and an atypical A-H(HRA) shorter than A-H(CS) was observed in 4 patients (9%). Successful ablation was obtained at the posteroseptum/midseptum in 32/7 patients with typical responses but only at the midseptum in all 4 patients with atypical responses (P = .0027). The atypical responses predicted a necessity for ablation at the midseptum, with positive and negative predictive values of 100% and 82%, respectively. The mechanism of an atypical response remains unclear but may involve an anatomical variation of Koch's triangle and/or the participation of a variant of the SP, including the superior SP, over which retrograde conduction was observed more frequently in patients with atypical responses (P = .0013).

CONCLUSIONS

Differential atrial EP predicts the ablation site for successfully curing S/F-AVNRT.

Для цитирования: Iizuka Takashi, Nakajima Tadashi, Tamura Shuntaro, Hasegawa Hiroshi, Kobari Takashi, Nakahara Shiro, Kurabayashi Masahiko, Kaneko Yoshiaki. Simple differential entrainment screens ablation strategy for slow-fast atrioventricular nodal reentrant tachycardia.. Pacing and clinical electrophysiology : PACE. 2020. DOI: 10.1111/pace.13946.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.