MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.180.4.1800929

Медицинская библиотека · AJR. American journal of roentgenology · 2003

Using a saline chaser to decrease contrast media in abdominal CT.

Dorio Paul J, Lee Fred T, Henseler Kevin P, Pilot Mark, Pozniak Myron A, Winter Thomas C, Shock Sarah A

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of this study was to compare hepatic tumor conspicuity on CT after injection of either 150 mL of contrast material or 100 mL of contrast material plus a 50-mL saline chaser.

SUBJECTS AND

METHODS

We evaluated 86 hypoattenuating liver metastases in 26 patients. Patients underwent CT in two sessions separated by a mean of 85 days: one time with 150 mL of contrast material and the other time with 100 mL of contrast material followed by a 50-mL saline chaser. The order of the sessions was randomized. Contrast material was administered via power injector and matched for injection rate and delay time. Attenuation values were obtained from normal liver tissue and metastases and from the spleen, kidney, aorta, and inferior vena cava.

RESULTS

The 150 mL dose of contrast material caused slightly greater liver and tumor attenuation than 100 mL of contrast material with a chaser (mean hepatic attenuation, 95.6 vs 89.8 H, respectively; p < 0.03, paired t test; mean tumor attenuation, 53.2 vs 49.1 H, respectively; r = 0.71, p = 0.09). The difference in conspicuity of liver lesions was slightly greater with 150 mL than with 100 mL with a chaser (46.8 H vs 44.2 H; r = 0.46, p = 0.08, paired t test), but was of doubtful clinical significance (2.6 H). Kidney, spleen, and vascular structures enhanced more with 150 mL than with 100 mL and a chaser.

CONCLUSION

Using 100 mL of contrast material and a saline chaser did not result in a meaningful difference in liver parenchyma attenuation or lesion conspicuity compared with using 150 mL of contrast medium alone. Routine use of a chaser for abdominal CT may yield cost savings and a decreased risk of contrast nephropathy.

Для цитирования: Dorio Paul J, Lee Fred T, Henseler Kevin P, Pilot Mark, Pozniak Myron A, Winter Thomas C, Shock Sarah A. Using a saline chaser to decrease contrast media in abdominal CT.. AJR. American journal of roentgenology. 2003. DOI: 10.2214/ajr.180.4.1800929.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.