Deep learning-based automatic segmentation of bone graft material after maxillary sinus augmentation.
Аннотация
OBJECTIVES
To investigate the accuracy and reliability of deep learning in automatic graft material segmentation after maxillary sinus augmentation (SA) from cone-beam computed tomography (CBCT) images.
MATERIALS AND
METHODS
One hundred paired CBCT scans (a preoperative scan and a postoperative scan) were collected and randomly allocated to training (n = 82) and testing (n = 18) subsets. The ground truths of graft materials were labeled by three observers together (two experienced surgeons and a computer engineer). A deep learning model including a 3D V-Net and a 3D Attention V-Net was developed. The overall performance of the model was assessed through the testing data set. The comparative accuracy and inference time consumption of the model-driven and manual segmentation (by two surgeons with 3 years of experience in dental implant surgery) were conducted on 10 CBCT scans from the test samples.
RESULTS
The deep learning model had a Dice coefficient (Dice) of 90.36 ± 2.53%, a 95% Hausdorff distance (HD) of 1.59 ± 0.82 mm, and an average surface distance (ASD) of 0.38 ± 0.11 mm. The proposed model only needed 7.2 s, while the surgeon took 19.15 min on average to complete a segmentation task. The overall performances of the model were significantly superior to those of surgeons.
CONCLUSIONS
The proposed deep learning model yielded a more accurate and efficient performance of automatic segmentation of graft material after SA than that of the two surgeons. The proposed model could facilitate a powerful system for volumetric change evaluation, dental implant planning, and digital dentistry.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.