The International journal of oral & maxillofacial implants · 2023

Extra-Short 4-mm Implants Splinted to 10-mm Implants in the Posterior Maxilla: 3-year Results.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gašperšič Rok, Povšič Katja, Dard Michel, Linder Susy, Gjurin Sonja Žarković, Oblak Čedomir

Аннотация

PURPOSE: To evaluate the 3-year success and survival rates of fixed prostheses supported by 4-mm extra-short implants splinted to 10-mm implants in patients with shortened maxillary arches and low maxillary sinus floors.

METHODS: A total of 11 patients with reduced alveolar bone heights due to low maxillary sinus floors received two or three titanium-zirconium tissue-level implants: one or two extra-short (4 mm) implants, and one implant 10 mm in length. After 6 months, prosthetic rehabilitation with splinted crowns connecting the 4- and 10-mm implants was performed. Follow-up visits and maintenance protocols were implemented every 4 to 6 months.

RESULTS: The 11 patients were treated with 11 10-mm implants and 17 4-mm implants. One extra-short implant failed and was removed before loading, and its planned design was modified from three splinted crowns to a bridge between the 10- and 4-mm implants. After 36 months, all (11/11) prosthetic rehabilitations connecting the 10-mm (11/11) and 4-mm (16/16) implants were functional. At the 10-mm implant sites, the median (interquartile range [IQR]) probing depth and marginal bone loss measured 2.9 mm (2.3 to 3.2) and 1.3 mm (1.0 to 1.5), respectively. At the 4-mm implant sites, the median (IQR) probing depth and marginal bone loss measured 2.9 mm (2.4 to 3.1) and 0.3 mm (0.1 to 0.5), respectively.

CONCLUSION: Prosthetic rehabilitation with splinted crowns connecting 4-mm and 10-mm implants showed promising outcomes in shortened maxillary dental arches after 3 years. Additional studies are needed to further validate these findings.