Evaluation of the Tasso-SST® capillary blood microsampling device for the measurement of endogenous uracil levels.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Menestrina Dewes Milene, Cé da Silva Laura, Fazenda Meireles Yasmin, Viana de Freitas Mariana, Frank Bastiani Marcos, Feltraco Lizot Lilian, Zilles Hahn Roberta, Venzon Antunes Marina, Linden Rafael

Аннотация

BACKGROUND: Uracil (U) plasma or serum levels can be used as surrogates of dihydropyrimidine dehydrogenase (DPD) activity, which is strongly related to the occurrence of severe or fatal toxicity after administration of fluoropyrimidines (FP) chemotherapy. Obtaining blood plasma or serum for U measurement usually requires a phlebotomy procedure by a qualified professional. An alternative to conventional blood drawn is the use of the Tasso-SST® device, which allows the collection of a small blood volume from skin capillaries. This study aimed to implement a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the determination of U in small serum samples and to compare U concentrations measured in venous plasma, obtained after phlebotomy, and serum obtained with the Tasso-SST® device.

METHODS: Fifty microliter samples were prepared through simple protein precipitation with trichloroacetic acid. Chromatographic separation was performed with a porous graphitic carbon stationary phase and mass spectrometric detection used positive electrospray ionization. The assay was validated according to international guidelines.

RESULTS: The linear range of the assay was 5-250 ng/mL. Measurement accuracy was in the range of 98.8-108.2%, inter-assay precision was 4.3-7.3%, and intra-assay precision was 3.4-6.1%. The average matrix effect was -6.42%. The extraction yield was 95-103.3%. U concentrations measured in serum obtained with the Tasso-SST® device and venous blood plasma were highly correlated (rs = 0.910, P < 0.0001), and no systematic or proportional bias between U levels measured in both matrices was found.

CONCLUSIONS: The use of blood microsampling with the Tasso-SST® device is a useful alternative for the measurement of U and the identification of patients with DPD deficiency.