DOI 10.3389/fphys.2020.570203

Медицинская библиотека · Frontiers in physiology · 2020

Left Atrial Enhancement Correlates With Myocardial Conduction Velocity in Patients With Persistent Atrial Fibrillation.

Ali Rheeda L, Qureshi Norman A, Liverani Silvia, Roney Caroline H, Kim Steven, Lim P Boon, Tweedy Jennifer H, Cantwell Chris D, Peters Nicholas S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Conduction velocity (CV) heterogeneity and myocardial fibrosis both promote re-entry, but the relationship between fibrosis as determined by left atrial (LA) late-gadolinium enhanced cardiac magnetic resonance imaging (LGE-CMRI) and CV remains uncertain.

OBJECTIVE

Although average CV has been shown to correlate with regional LGE-CMRI in patients with persistent AF, we test the hypothesis that a localized relationship exists to underpin LGE-CMRI as a minimally invasive tool to map myocardial conduction properties for risk stratification and treatment guidance.

METHOD: 3D LA electroanatomic maps during LA pacing were acquired from eight patients with persistent AF following electrical cardioversion. Local CVs were computed using triads of concurrently acquired electrograms and were co-registered to allow correlation with LA wall intensities obtained from LGE-CMRI, quantified using normalized intensity (NI) and image intensity ratio (IIR). Association was evaluated using multilevel linear regression.

RESULTS

An association between CV and LGE-CMRI intensity was observed at scales comparable to the size of a mapping electrode: -0.11 m/s per unit increase in NI (P < 0.001) and -0.96 m/s per unit increase in IIR (P < 0.001). The magnitude of this change decreased with larger measurement area. Reproducibility of the association was observed with NI, but not with IIR.

CONCLUSION

At clinically relevant spatial scales, comparable to area of a mapping catheter electrode, LGE-CMRI correlates with CV. Measurement scale is important in accurately quantifying the association of CV and LGE-CMRI intensity. Importantly, NI, but not IIR, accounts for changes in the dynamic range of CMRI and enables quantitative reproducibility of the association.

Для цитирования: Ali Rheeda L, Qureshi Norman A, Liverani Silvia, Roney Caroline H, Kim Steven, Lim P Boon, Tweedy Jennifer H, Cantwell Chris D, Peters Nicholas S. Left Atrial Enhancement Correlates With Myocardial Conduction Velocity in Patients With Persistent Atrial Fibrillation.. Frontiers in physiology. 2020. DOI: 10.3389/fphys.2020.570203.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.