m+Medelevator.RU
← Поиск публикаций
JACC. Clinical electrophysiology · 2020

A Lattice-Tip Temperature-Controlled Radiofrequency Ablation Catheter: Durability of Pulmonary Vein Isolation and Linear Lesion Block.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Reddy Vivek Y, Neužil Petr, Peichl Petr, Rackauskas Gediminas, Anter Elad, Petru Jan, Funasako Moritoshi, Minami Kentaro, Aidietis Audrius, Marinskis Germanas, Natale Andrea, Nakagawa Hiroshi, Jackman Warren M, Kautzner Josef

Аннотация

OBJECTIVES: This study was designed to evaluate lesion durability on invasive electrophysiologic remapping.

BACKGROUND: The lattice-tip catheter generates a large thermal footprint during temperature-controlled irrigated radiofrequency ablation. In a first-in-human study, this catheter performed rapid point-by-point pulmonary vein isolation (PVI) and other linear atrial ablations.

METHODS: In a prospective 3-center single-arm study, paroxysmal or persistent atrial fibrillation patients underwent PVI and, as needed, linear ablation at the cavotricuspid isthmus (CTI), mitral isthmus (MI), and/or left atrial roof; no other atrial substrate was ablated. Using the lattice catheter and a custom electroanatomic mapping system, temperature-controlled (Tmax 73° to 80°C; 2 to 7 s) point-by-point ablation was performed. Patients were followed for 12 months.

RESULTS: A total of 65 patients (61.5% paroxysmal/38.5% persistent) underwent ablation: PVI in 65, MI in 22, left atrial roof in 24, and CTI in 48 patients. At a median of 108 days after the index procedure, protocol-mandated remapping was performed in 27 patients. The pulmonary veins (PVs) remained durably isolated in all but 1 reconnected PV-translating to durable isolation in 99.1% of PVs, or 96.3% of patients with all PVs isolated. Of 47 linear atrial lesions initially placed during the index procedure, durability was observed in 10 of 11 (90.9%) MI lines, all 11 (100%) roof lines, and all 25 (100%) CTI lines. After a median follow-up of 270 days, the 12-month Kaplan-Meier estimate for freedom from atrial arrhythmias was 94.4 ± 3.2%.

CONCLUSIONS: Temperature-controlled lattice-tip point-by-point ablation showed not only highly durable PVI lesion sets, but also durable contiguity of linear atrial lesions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты