MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00380-020-01563-7

Медицинская библиотека · Heart and vessels · 2020

The impact of the dominant frequency of body surface electrocardiography in patients with persistent atrial fibrillation.

Murase Yosuke, Inden Yasuya, Shibata Rei, Yanagisawa Satoshi, Fujii Aya, Ando Monami, Otake Noriaki, Takenaka Masaki, Funabiki Junya, Sakamoto Yusuke, Murohara Toyoaki

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

The dominant frequency (DF) of atrial fibrillation (AF) reflects atrial electrical activity. However, the relationship between DF measured using surface electrocardiography (ECG) and AF ablation success remains unclear. This study aimed to clarify whether the DF of surface ECG in patients with persistent AF could predict arrhythmia recurrence after catheter ablation. We investigated 125 patients with persistent AF who underwent catheter ablation between January 2009 and December 2016. Thirty-four patients (27%) had arrhythmia recurrence after catheter ablation. These patients showed a significantly high DF value in leads aVL (7.2 ± 0.7 Hz vs 6.6 ± 0.9 Hz, p < 0.001) and V1 (7.4 ± 0.8 Hz vs 6.7 ± 0.7 Hz, p < 0.001). We set the cutoff value of DF as 6.9 Hz in lead aVL (sensitivity, 80%; specificity, 63%) and as 7.1 Hz in lead V1 (sensitivity, 72%; specificity, 67%). Patients with DF < 6.9 Hz in lead aVL showed a significantly higher recurrence-free rate than those with DF ≥ 6.9 Hz (88% vs 45%; p < 0.001). Patients with DF of < 7.1 Hz in lead V1 showed a significantly higher recurrence-free rate than those with DF of  ≥ 7.1 (87% vs 47%; p < 0.001). Patients with a high DF in leads aVL and V1 showed a lower success rate of persistent AF ablation. The DF measured from surface ECG can be a useful marker to predict ablation success.

Для цитирования: Murase Yosuke, Inden Yasuya, Shibata Rei, Yanagisawa Satoshi, Fujii Aya, Ando Monami, Otake Noriaki, Takenaka Masaki, Funabiki Junya, Sakamoto Yusuke, Murohara Toyoaki. The impact of the dominant frequency of body surface electrocardiography in patients with persistent atrial fibrillation.. Heart and vessels. 2020. DOI: 10.1007/s00380-020-01563-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.