PURPOSE: Rapid ventricular pacing (RVP) was reported to improve the cooling effects of the cryoballoon (CB). The aim of this study was to investigate the safety and efficacy of RVP for left atrial posterior wall isolation (PWI) by the CB.

METHODS

One hundred consecutive patients (males 80, mean age 63 ± 10 years) with persistent atrial fibrillation underwent left atrial roof (LA-RB) and bottom block line (LA-BB) creation by CB to achieve PWI. Patients were randomized into two groups according to whether they underwent PWI with (RVP group, n = 50) or without RVP (control group, n = 50).

RESULTS

The nadir CB temperature (NCT) during the LA-RB and LA-BB creation was significantly lower in the RVP group than control group (LA-RB - 45.7 °C and - 43.9 °C, p < 0.001, and LA-BB - 42.4 °C and - 40.0 °C, p < 0.001). The success rate of the LA-RB creation was significantly higher in the RVP group than the control group (98% vs. 88%, p = 0.039), however, there were no significant differences regarding the LA-BB creation (66% vs. 52%, p = 0.15) and PWI (66% vs. 50%, p = 0.1) between the two groups. The PWI success rate did not differ whether CB freezing was prematurely terminated due to an excessive luminal esophageal temperature (LET) drop in the RVP group (65.8% vs. 66.7%, respectively, p = 0.96).

CONCLUSIONS

RVP significantly decreased the NCT during the CB application resulting in the significant improvement of success rate of the LA-RB. The advantage of RVP in terms of the accomplishing PWI was not affected even when the CB freezing was prematurely terminated due to an excessive LET drop.

Для цитирования: Nishimura Takuro, Okishige Kaoru, Yamauchi Yasuteru, Shigeta Takatoshi, Nakamura Rena, Hirao Tastuhiko, Sasano Tetsuo, Hirao Kenzo. Clinical impact of rapid ventricular pacing on the left atrial posterior wall isolation by a cryoballoon application: a randomized controlled trial.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2020. DOI: 10.1007/s10840-019-00641-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.