Effect on refractive outcomes after cataract surgery of intraocular lens constant personalization using the Haigis formula.

Charalampidou Sofia, Cassidy Lorraine, Ng Eugene, Loughman James, Nolan John, Stack Jim, Beatty Stephen

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To quantify the effect on refractive outcomes after cataract surgery of personalization of Haigis intraocular lens (IOL) constants for a given surgeon-IOL combination.

SETTING

Institute of Eye Surgery and Institute of Vision Research, Whitfield Clinic, Butlerstown North, Waterford, Ireland.

METHODS

Personalization of Haigis IOL constants was performed using a series of 248 suitable eyes after biometry by partial coherence interferometry (IOLMaster) and IOL prediction based on optimized IOL constants derived from pooled data from the User Group for Laser Interference Biometry web site. A mean error of prediction and a mean absolute error were then calculated using the personalized IOL constants and compared with those derived using optimized IOL constants, allowing evaluation and quantification of the maximum realizable refractive benefits (if any) of personalization.

RESULTS

There was no statistically significant difference between personalized and optimized Haigis IOL constants in absolute error or the proportion of eyes within +/-1.00 diopters (D), +/-0.50 D, or +/-0.25 D of the target postoperative refraction in all eyes, short eyes (axial length [AL] <22 mm; n = 19), average eyes (AL > or =22 mm and <24.5 mm; n = 149), or long eyes (AL >24.5 mm; n = 46) (all P>.05, McNemar test). Ten eyes with a short AL had a smaller absolute error (by > or =0.30 D) in association with personalized IOL constants.

CONCLUSION

Personalized Haigis IOL constants showed marginal, but statistically nonsignificant, refractive advantages over optimized Haigis IOL constants, but only in eyes with a short AL. FINANCIAL DISCLAIMER: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Charalampidou Sofia, Cassidy Lorraine, Ng Eugene, Loughman James, Nolan John, Stack Jim, Beatty Stephen. Effect on refractive outcomes after cataract surgery of intraocular lens constant personalization using the Haigis formula.. Journal of cataract and refractive surgery. 2010. DOI: 10.1016/j.jcrs.2009.12.050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.