PURPOSE: To report the results of Descemet-stripping automated endothelial keratoplasty (DSAEK) in eyes with toxic anterior segment syndrome (TASS) after cataract surgery.

SETTING

Department of Ophthalmology, Istanbul University Cerrahpaşa Medical Faculty, Istanbul, Turkey.

METHODS

In this prospective study of consecutive patients who had DSAEK for corneal failure due to TASS, the main outcome measures were corneal clarity, mean spherical equivalent (SE) refraction, preoperative and postoperative visual acuities, central corneal thickness, and endothelial cell count (ECC).

RESULTS

The mean follow-up in the 10 eyes (10 patients) was 17.1 months +/- 2.4 (SD). There were no graft dislocations postoperatively, and no graft required repositioning. All grafts were clear at 12 months. Two eyes had initial graft rejection that resolved with treatment. All eyes had improved postoperative corrected distance visual acuity, with 7 eyes (70%) attaining 0.5 or better. The mean SE refraction in measurable cases (5 eyes) was 1.2 +/- 0.6 preoperatively and 0.9 +/- 1.0 postoperatively (P = .141). The decrease in mean pachymetry from preoperatively (691 +/- 15 microm) to 12 months postoperatively (614 +/- 23 microm) was statistically significant (P = .005). The mean ECC was 2740 +/- 236 cells/mm(2) preoperatively, 1690 +/- 209 cells/mm(2) at 6 months, and 1683 +/- 206 cells/mm(2) at 12 months. The decrease between preoperatively and 6 and 12 months (P = .05) and between 6 months and 12 months (P = .008) was statistically significant.

CONCLUSION

Descemet-stripping automated endothelial keratoplasty was safe and effective in eyes with TASS-associated corneal edema, yielding encouraging surgical and visual outcomes.

Для цитирования: Arslan Osman S, Unal Mustafa, Arici Ceyhun, Görgün Ebru, Yenerel Melda, Cicik Erdoğan. Descemet-stripping automated endothelial keratoplasty in eyes with toxic anterior segment syndrome after cataract surgery.. Journal of cataract and refractive surgery. 2010. DOI: 10.1016/j.jcrs.2009.12.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.