Two-year follow-up after implantation of diffractive aspheric silicone multifocal intraocular lenses.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yoshino Mami, Bissen-Miyajima Hiroko, Oki Shinichi, Minami Keiichiro, Nakamura Kunihiko
Аннотация
PURPOSE: To evaluate the stability of visual performance after implantation of a diffractive aspheric silicone multifocal intraocular lens (MIOL).
METHODS: Thirty eyes of 15 patients received the Tecnis MIOL ZM900 (Abbot Medical Optics) after cataract extraction at Tokyo Dental College Suidobashi Hospital. The uncorrected and best-corrected distance visual acuities (UCDVA, BCDVA); uncorrected, distance-corrected and best-corrected near VAs (UCNVA, DCNVA and BCNVA); spherical equivalent refraction, spectacle independence, contrast sensitivity and posterior capsule opacification (PCO) were measured at 1 week; 1, 3 and 6 months; and 1 and 2 years postoperatively.
RESULTS: Two years postoperatively, the UCDVA was 0.01 logMAR, BCDVA -0.09 logMAR, UCNVA 0.19 logMAR, DCNVA 0.1 logMAR and BCNVA 0.04 logMAR. There was no significant change from 1 week through 2 years. The percent of spherical equivalent refraction error within ± 0.5 diopter was 63.4% at 2 years. No patient required spectacles for reading; two patients have used spectacles for intermediate vision when necessary. One eye underwent Nd:YAG laser posterior capsulotomy because of PCO.
CONCLUSION: The visual performance after implantation of the Tecnis MIOL was stable for 2 years. A low rate of PCO contributed to the long-term visual performance.
METHODS: Thirty eyes of 15 patients received the Tecnis MIOL ZM900 (Abbot Medical Optics) after cataract extraction at Tokyo Dental College Suidobashi Hospital. The uncorrected and best-corrected distance visual acuities (UCDVA, BCDVA); uncorrected, distance-corrected and best-corrected near VAs (UCNVA, DCNVA and BCNVA); spherical equivalent refraction, spectacle independence, contrast sensitivity and posterior capsule opacification (PCO) were measured at 1 week; 1, 3 and 6 months; and 1 and 2 years postoperatively.
RESULTS: Two years postoperatively, the UCDVA was 0.01 logMAR, BCDVA -0.09 logMAR, UCNVA 0.19 logMAR, DCNVA 0.1 logMAR and BCNVA 0.04 logMAR. There was no significant change from 1 week through 2 years. The percent of spherical equivalent refraction error within ± 0.5 diopter was 63.4% at 2 years. No patient required spectacles for reading; two patients have used spectacles for intermediate vision when necessary. One eye underwent Nd:YAG laser posterior capsulotomy because of PCO.
CONCLUSION: The visual performance after implantation of the Tecnis MIOL was stable for 2 years. A low rate of PCO contributed to the long-term visual performance.