DOI 10.1111/j.1755-3768.2009.01792.x
Two-year follow-up after implantation of diffractive aspheric silicone multifocal intraocular lenses.
Аннотация
PURPOSE: To evaluate the stability of visual performance after implantation of a diffractive aspheric silicone multifocal intraocular lens (MIOL).
METHODS
Thirty eyes of 15 patients received the Tecnis MIOL ZM900 (Abbot Medical Optics) after cataract extraction at Tokyo Dental College Suidobashi Hospital. The uncorrected and best-corrected distance visual acuities (UCDVA, BCDVA); uncorrected, distance-corrected and best-corrected near VAs (UCNVA, DCNVA and BCNVA); spherical equivalent refraction, spectacle independence, contrast sensitivity and posterior capsule opacification (PCO) were measured at 1 week; 1, 3 and 6 months; and 1 and 2 years postoperatively.
RESULTS
Two years postoperatively, the UCDVA was 0.01 logMAR, BCDVA -0.09 logMAR, UCNVA 0.19 logMAR, DCNVA 0.1 logMAR and BCNVA 0.04 logMAR. There was no significant change from 1 week through 2 years. The percent of spherical equivalent refraction error within ± 0.5 diopter was 63.4% at 2 years. No patient required spectacles for reading; two patients have used spectacles for intermediate vision when necessary. One eye underwent Nd:YAG laser posterior capsulotomy because of PCO.
CONCLUSION
The visual performance after implantation of the Tecnis MIOL was stable for 2 years. A low rate of PCO contributed to the long-term visual performance.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.