DOI 10.1016/j.jcrs.2009.04.038

Медицинская библиотека · Journal of cataract and refractive surgery · 2009

Intraocular lens power adjustment nomogram after laser in situ keratomileusis.

Diehl Joseph W, Yu Fei, Olson Michael D, Moral Joel N, Miller Kevin M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To develop a nomogram for improving the accuracy of intraocular lens (IOL) power calculation at the time of cataract surgery based on the manifest refraction spherical equivalent (MRSE) change produced by laser in situ keratomileusis (LASIK).

SETTING

University-based clinical practice, Jules Stein Eye Institute, Los Angeles, California, USA.

METHODS

This was a retrospective review of the records of consecutive patients who had cataract surgery after LASIK. Spherical equivalent refractive data before and after LASIK and cataract surgery were recorded. The differences between the targeted postoperative refractive errors after cataract surgery and the achieved refractive errors were plotted against the LASIK-induced MRSE change, yielding postoperative refractive errors to target during IOL power calculation to achieve emmetropia.

RESULTS

Thirty-two eyes of 23 patients were identified; 25 eyes had myopic LASIK and 7, hyperopic LASIK. Regression analysis yielded the following polynomial relationship: target postoperative refractive error (D) to achieve emmetropia during IOL power calculation = -0.018(MRSE Change)(2) + 0.192(MRSE Change) - 0.062. The outcomes in 97% of eyes fell within +/-1.00 D of the value predicted by this formula.

CONCLUSIONS

A 2nd-order polynomial relationship was found between LASIK-induced MRSE change and the MRSE error after cataract surgery. From this equation, a simple adjustment nomogram was generated and put into a look-up table format. The formula and nomogram should improve IOL power calculation accuracy in post-LASIK eyes when the MRSE change is known.

Для цитирования: Diehl Joseph W, Yu Fei, Olson Michael D, Moral Joel N, Miller Kevin M. Intraocular lens power adjustment nomogram after laser in situ keratomileusis.. Journal of cataract and refractive surgery. 2009. DOI: 10.1016/j.jcrs.2009.04.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.