m+Medelevator.RU
← Поиск публикаций
Ophthalmology · 2009

Effect of intraocular lens asphericity on quality of vision after cataract removal: an intraindividual comparison.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kohnen Thomas, Klaproth Oliver K, Bühren Jens

Аннотация

PURPOSE: To determine the effect of intraocular lens (IOL) asphericity on quality of vision after cataract removal.

DESIGN: Intraindividual, prospective, randomized clinical trial.

PARTICIPANTS: Twenty-six cataract patients received 2, one-piece, blue-light-filtering hydrophobic acrylic IOLs each.

METHODS: One eye was implanted with a spherical (SN60AT, Alcon) and the contralateral eye with an aspheric (SN60WF, Alcon) IOL with -0.2 mum spherical aberration (SA). All trial-specific measurements (corneal topography, wavefront sensing, high-contrast visual acuity [HCVA], contrast sensitivity [CS]) were performed 6 months after surgery. A paired Student t-test or Wilcoxon test was used to check intergroup differences.

MAIN OUTCOME MEASURES: Absolute values and intraindividual differences (Delta(i)) of corneal and ocular higher order aberrations and best-corrected visual Strehl ratio based on the optical transfer function (BCVSOTF) values for virtual pupil diameters of 3, 4, 5, and 6 mm were computed. Photopic and mesopic HCVA, photopic, and high-mesopic CS as well as high-mesopic disability glare (DG) were measured using the Frankfurt-Freiburg Contrast and Acuity Test System.

RESULTS: No intergroup difference of demographic data, pupillometry, and corneal aberrations were observed. Coma and trefoil root mean square and SA were significantly lower in the aspheric group resulting in higher BCVSOTF, mesopic HCVA, and photopic and high mesopic CS. All Delta(i) values with exception of photopic HCVA and DG indicated significantly better performance of the aspheric IOL.

CONCLUSIONS: An aspheric IOL with -0.2 microm SA provide higher quality of vision than spherical IOL in terms of retinal image quality, mesopic HCVA and CS.

FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosures may be found after the references.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты