MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2009.03.052

Медицинская библиотека · Ophthalmology · 2009

Effect of intraocular lens asphericity on quality of vision after cataract removal: an intraindividual comparison.

Kohnen Thomas, Klaproth Oliver K, Bühren Jens

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the effect of intraocular lens (IOL) asphericity on quality of vision after cataract removal.

DESIGN

Intraindividual, prospective, randomized clinical trial.

PARTICIPANTS

Twenty-six cataract patients received 2, one-piece, blue-light-filtering hydrophobic acrylic IOLs each.

METHODS

One eye was implanted with a spherical (SN60AT, Alcon) and the contralateral eye with an aspheric (SN60WF, Alcon) IOL with -0.2 mum spherical aberration (SA). All trial-specific measurements (corneal topography, wavefront sensing, high-contrast visual acuity [HCVA], contrast sensitivity [CS]) were performed 6 months after surgery. A paired Student t-test or Wilcoxon test was used to check intergroup differences.

MAIN OUTCOME MEASURES: Absolute values and intraindividual differences (Delta(i)) of corneal and ocular higher order aberrations and best-corrected visual Strehl ratio based on the optical transfer function (BCVSOTF) values for virtual pupil diameters of 3, 4, 5, and 6 mm were computed. Photopic and mesopic HCVA, photopic, and high-mesopic CS as well as high-mesopic disability glare (DG) were measured using the Frankfurt-Freiburg Contrast and Acuity Test System.

RESULTS

No intergroup difference of demographic data, pupillometry, and corneal aberrations were observed. Coma and trefoil root mean square and SA were significantly lower in the aspheric group resulting in higher BCVSOTF, mesopic HCVA, and photopic and high mesopic CS. All Delta(i) values with exception of photopic HCVA and DG indicated significantly better performance of the aspheric IOL.

CONCLUSIONS

An aspheric IOL with -0.2 microm SA provide higher quality of vision than spherical IOL in terms of retinal image quality, mesopic HCVA and CS.

FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosures may be found after the references.

Для цитирования: Kohnen Thomas, Klaproth Oliver K, Bühren Jens. Effect of intraocular lens asphericity on quality of vision after cataract removal: an intraindividual comparison.. Ophthalmology. 2009. DOI: 10.1016/j.ophtha.2009.03.052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.