Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2009

Comparison of pseudophakic visual quality in spherical and aspherical intraocular lenses.

Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cui Hongguang, Hu Rongrong, Zhang Yingying, Lou Dinghua

Аннотация

OBJECTIVE: This study compares the visual performance of spherical and aspherical intraocular lenses (IOLs) by measuring higher-order aberration and contrast sensitivity (CS) values.

DESIGN: Prospective controlled study.

PARTICIPANTS: Fifty-seven patients with age-related cataract (61 eyes).

METHODS: Patients were randomly allocated to 1 of 3 groups and implanted with either aspherical IOLs, Acrysof IQ (SN60WF) or Tecnis Z9001, or a spherical IOL, Acrysof Natural. Patients underwent routine examinations, including visual acuity, slit-lamp checks, and best-corrected visual acuity (BCVA), as well as measurement of higher-order aberrations and CS values, preoperatively and at 1 week, 1 month, and 2 months postoperatively.

RESULTS: All the patients had a BCVA better than 20/30 postoperatively. The spherical aberrations of the IQ group and Tecnis group were both lower than in the Natural (control) group (IQ: p < 0.05; Tecnis: p < 0.05); there was no significant difference in coma and higher-order aberration. No statistically significant difference was found in spherical aberration, coma, or higher-order aberration between the IQ and Tecnis groups. Under glare conditions, the CS values of the 2 aspherical IOLs were obviously better (IQ: p < 0.05; Tecnis: p < 0.05) than the CS value of the spherical IOL group at low frequency (IQ: 6.3 degrees, Tecnis: 4.0 degrees); under non-glare conditions there was a significant difference in CS values between the aspherical IOL groups and the control group (IQ: p < 0.01; Tecnis: p < 0.01) at low frequency (both 6.3 degrees). There was no statistical difference between the IQ and the Tecnis groups with or without glare.

CONCLUSIONS: An aspherical IOL can effectively reduce spherical aberration after cataract surgery, enhance CS values, and improve visual quality compared with traditional spherical IOLs for age-related cataract. However, there was no statistically significant difference in postoperative aberration and CS values between the Acrysof IQ and Tecnis Z9001 aspherical IOLs.