DOI 10.1016/j.ajo.2009.03.027

Медицинская библиотека · American journal of ophthalmology · 2009

Three-year follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification.

Nekolová Jana, Jirásková Nada, Pozlerová Jana, Rozsíval Pavel

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To prospectively compare the degree of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods during the 3-year follow-up period.

DESIGN

Prospective, randomized clinical trial.

METHODS

Setting at the Department of Ophthalmology, University Hospital in Hradec Králové. Patients with bilateral cataract were included. AquaLase was used in the right eye and NeoSoniX in the left eye of each patient. The AcrySof SA60AT intraocular lens (Alcon Laboratories, Fort Worth, Texas, USA) was implanted in all eyes. The Evaluation of Posterior Capsule Opacification (EPCO) 2000 software (Developed by Tetz MR and associates, Berlin, Germany) and the Open-Access Systematic Capsule Assessment (OSCA) system (Devised by Aslam TM, Edinburgh, United Kingdom) were used for PCO assessment 1, 2, and 3 years after cataract surgery.

RESULTS

Fifty patients were analyzed 1 year, 47 patients 2 years, and 46 patients 3 years after cataract surgery. Mean EPCO 2000 values were for the AquaLase group 0.324 +/- 0.305 and for the NeoSoniX group 0.298 +/- 0.341 (P = .53) 1 year after surgery, for the AquaLase group 0.429 +/- 0.322 and for the NeoSoniX group 0.478 +/- 0.337 (P = .30) 2 years after surgery, and for the AquaLase group 0.582 +/- 0.506 and for the NeoSoniX group 0.594 +/- 0.515 (P = .87) 3 years after surgery. The OSCA results were for the AquaLase group 0.7097 +/- 0.3778 and for the NeoSoniX group 0.8584 +/- 0.4323 (P = .046) 1 year after surgery, for the AquaLase group 0.7515 +/- 0.4555 and for the NeoSoniX group 0.8103 +/- 0.4498 (P = .44) 2 years after surgery, and for the AquaLase group 0.9667 +/- 0.736 and for the NeoSoniX group 0.9540 +/- 0.5250 (P = .91) 3 years after surgery. Neodymium-yttrium-aluminun-garnet capsulotomy rate for AquaLase vs NeoSoniX was 0:1 eyes 1 year, 1:3 eyes 2 years, and 1:4 eyes 3 years after surgery. No significant difference between those 2 groups was established, except the OSCA outcomes 1 year postoperatively.

CONCLUSION

There was only minimal PCO difference between these 2 approaches, AquaLase and NeoSoniX. Neither AquaLase nor NeoSoniX technique was able to prevent a natural progression of PCO.

Для цитирования: Nekolová Jana, Jirásková Nada, Pozlerová Jana, Rozsíval Pavel. Three-year follow-up of posterior capsule opacification after AquaLase and NeoSoniX phacoemulsification.. American journal of ophthalmology. 2009. DOI: 10.1016/j.ajo.2009.03.027.