Correction of residual hyperopia after cataract surgery using the light adjustable intraocular lens technology.

Chayet Arturo, Sandstedt Christian A, Chang Shiao H, Rhee Paul, Tsuchiyama Barbara, Schwartz Daniel

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine whether residual hyperopia could be corrected postoperatively using the light adjustable lens technology in patients undergoing cataract surgery and light adjustable lens implantation.

DESIGN

Prospective, nonrandomized clinical trial.

METHODS

Fourteen eyes of 14 patients were studied. The manifest refraction, uncorrected visual acuity (UCVA), and best-corrected visual acuity (BCVA) were determined with follow-up time to determine the achieved refractive corrections and their stability.

RESULTS

Of 14 eyes, 13 eyes (92.9%) achieved +/- 0.25 diopters (D) of the target refraction at one day post lock-in, with 100% of the eyes achieving the targeted refractive adjustment within 0.5 D or better up to six months postoperative follow-up. All eyes treated show no change in manifest spherical refraction >0.25 D between one day post lock-in, and three and six months postoperative visits. The data demonstrate the stability of the achieved refractive change after the adjustment and lock-in procedures. The mean rate of change was 0.006 D per month, which is six times more stable than that of refractive procedures.

CONCLUSIONS

Residual hyperopia errors in the range of +0.25 to +2.0 D were successfully corrected with precision and significant improvement in UCVA and without compromising BCVA using the light adjustable intraocular lens technology.

Для цитирования: Chayet Arturo, Sandstedt Christian A, Chang Shiao H, Rhee Paul, Tsuchiyama Barbara, Schwartz Daniel. Correction of residual hyperopia after cataract surgery using the light adjustable intraocular lens technology.. American journal of ophthalmology. 2008. DOI: 10.1016/j.ajo.2008.08.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.