MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.compbiomed.2021.104871

Медицинская библиотека · Computers in biology and medicine · 2021

Artificial intelligence for quality control of oscillometry measures.

Veneroni Chiara, Acciarito Andrea, Lombardi Enrico, Imeri Gianluca, Kaminsky David A, Gobbi Alessandro, Pompilio Pasquale P, Dellaca' Raffaele L

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The forced oscillation technique (FOT) allows non-invasive lung function testing during quiet breathing even without expert guidance. However, it still relies on an operator for excluding breaths with artefacts such as swallowing, glottis closure and coughing. This manual selection is operator-dependent and time-consuming. We evaluated supervised machine learning methods to exclude breaths with artefacts from data analysis automatically.

METHODS

We collected 932 FOT measurements (Resmon Pro Full, Restech) from 155 patients (6-87 years) following the European Respiratory Society (ERS) technical standards. Patients were randomly assigned to either a training (70%) or test set. For each breath, we computed 71 features (including anthropometric, pressure stimulus, breathing pattern, and oscillometry data). Univariate filter, multivariate filter and wrapper methods for feature selection combined with several classification models were considered.

RESULTS

Trained operators identified 4333 breaths with- and 10244 without artefacts. Features selection performed by a wrapper method combined with an AdaBoost tree model provided the best performance metrics on the test set: Balanced Accuracy = 85%; Sensitivity = 79%; Specificity = 91%; AUC-ROC = 0.93. Differences in FOT parameters computed after manual or automatic breath selection was less than ∼0.25 cmH2O*s/L for 95% of cases.

CONCLUSION

Supervised machine-learning techniques allow reliable artefact detection in FOT diagnostic tests. Automating this process is fundamental for enabling FOT for home monitoring, telemedicine, and point-of-care diagnostic applications and opens new scenarios for respiratory and community medicine.

Для цитирования: Veneroni Chiara, Acciarito Andrea, Lombardi Enrico, Imeri Gianluca, Kaminsky David A, Gobbi Alessandro, Pompilio Pasquale P, Dellaca' Raffaele L. Artificial intelligence for quality control of oscillometry measures.. Computers in biology and medicine. 2021. DOI: 10.1016/j.compbiomed.2021.104871.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.