m+Medelevator.RU
← Поиск публикаций
Journal of biomechanics · 2021

Influence of position and angulation of a voice prosthesis on the aerodynamics of the pseudo-glottis.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Santos Fernando H T, da Silva Andrey R, Tourinho André M C, Erath Byron

Аннотация

The use of a tracheoesophageal valve, also known as voice prosthesis, is currently the most appealing solution for recovering the ability to speak in subjects who have undergone a total laryngectomy. The prosthesis allows the passage of air from the trachea to the esophagus, thereby promoting the flow-induced vibration of the subject's pharyngoesophageal segment. In turn, the pharyngoesophageal segment modulates the air flow from the lungs into the subject's vocal tract, acting as an alternative source of acoustic energy to generate voice. The vibration of the pharyngoesophageal segment will likely depend on the aerodynamic forces acting on its wall, which will be defined by the flow characteristics downstream from the valve's outlet. Previous works have investigated the pressure drop across different prosthesis designs with both in-vitro and in-vivo experiments. Nevertheless, the aerodynamic aspects of the flow in the tracheoesophageal region have only been investigated experimentally in an idealized geometry. This work investigates the influence of the prosthesis position on the aerodynamic behavior of the pharyngoesophageal segment in terms of wall pressure distribution and characteristics of the velocity field. The investigations were carried out with a static model of the tracheoesophageal region based on the finite volume method and a Reynolds-averaged Navier-Stokes solver. The geometry of the system was based on computed tomography images obtained from laryngectomized subjects during phonation at different voice registers and included the geometry of a commercially available voice prosthesis. The results suggest that the position and angulation of the voice prosthesis have a minor influence on the pressure loss along the tracheoesophageal segment and on the pressure distribution on the pharyngoesophageal segment's wall.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты