MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvc.2025.12.003

Медицинская библиотека · Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology · 2025

Clinical value of the tissue Doppler derived index of myocardial performance (Tei index) in cats with hypertrophic cardiomyopathy.

Naseri A, Ider M, Sahin H B, Durgut M K, Iyigun S S, Guzelbektes H

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION/

OBJECTIVES

The aim of the present study was to investigate the left ventricular Index of Myocardial Performance (IMP) by tissue Doppler echocardiography in cats with hypertrophic cardiomyopathy (HCM).

ANIMALS, MATERIALS AND

METHODS

Twenty cats with HCM and 10 healthy cats were included in the study. Clinical examination, electrocardiography, blood pressure measurement, thoracic radiography and transthoracic echocardiography were performed in both healthy and HCM cats. Left ventricular IMP was assessed by tissue Doppler imaging (TDI) echocardiography.

RESULTS

Systolic dysfunction was observed in 11 cats (55 %), and diastolic dysfunction was present in all cats with HCM. Although the isovolumic contraction time (IVCT) and ejection time (ET) were significantly shorter in cats with HCM, the IMP was not significantly different between the study groups. Peak velocity of early diastolic mitral annular motion as determined by pulsed wave Doppler (E') and respiratory rate (RR) were identified as potential predictors of mortality.

STUDY LIMITATIONS: Small sample size and lack of time-adjusted survival analysis may reduce the strength of prognostic conclusions.

CONCLUSIONS

Our study shows that both diastolic and systolic dysfunction are present in cats with HCM and that these alterations affect left ventricular IMP, potentially limiting its clinical applicability. Furthermore, low E' and increased RR were identified as potential predictors of mortality in cats with HCM.

Для цитирования: Naseri A, Ider M, Sahin H B, Durgut M K, Iyigun S S, Guzelbektes H. Clinical value of the tissue Doppler derived index of myocardial performance (Tei index) in cats with hypertrophic cardiomyopathy.. Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology. 2025. DOI: 10.1016/j.jvc.2025.12.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.