PURPOSE: To quantify the effect of the significant ocular bio-parameters and the nomograms for an optimal Implantable Collamer Lens (ICL) vault.

SETTING

Regional eye hospital.

DESIGN

Retrospective.

METHODS

Consecutive 103 patients (200 eyes) with implantation of ICL V4c were analyzed to find the important anterior eye parameters and the nomograms to achieve the optimal vaults (250 to 750 µm).

RESULTS

The study found that anterior chamber width (ACW, β = 5.17, p = 0.0003), angle-to-angle (ATA, β = -3.1, p = 0.0084), and crystalline lens rise (β = 0.0044, p = 0.0007) are the significant parameters for predicting optimal vaults. For the ACW, a 10 µm increase from its mean (11.76 mm) would lead to 1.76 times higher odds for an optimized vault while holding all other variables constant. In contrast, a 100 µm increase from the ATA mean (11.63 mm) was associated with a 9.5% reduction in odds to achieve an optimal vault. CASIA2-NK or the Dougherty nomogram had similar higher odds to achieve an optimal vault than that by OCOS (odds ratio = 5.8, p = 0.0069; odds ratio = 3.3, p = 0.024). The magnitude of the difference between ACW and ATA was significantly associated with the odds of optimal vault.

CONCLUSIONS

The ACW and the ATA are both significant predictors for achieving an optimal vault; their size difference may bear significant value for ICL optimal vaults. CASIA2, along with its integrated formula, may be a stand-alone handy option for ICL size selection for the East Asian population.

Для цитирования: Bifei Lan, Li Cai, Danli Xin, Hongyan Yao, Shanjun Wu, Lingyun Cheng. A quantitative assessment of the vault optimization along with the ocular bio-parameters and Implantable Collamer Lens sizing nomograms.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001700.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.